Warranty: 1 year
Model Number: YC
Type: Induction Motor
Frequency: 50Hz
Phase: Single-phase
Protect Feature: Totally Enclosed
AC Voltage: 208-230 / 240 V
Efficiency: IE 1
Protection Class: IP44/IP54
Insulation Class: B/F
Cooling Method: ICO141
Duty: Continuous(S1)
Rated Voltage: 220±5%
Mounting: B3/B5/B35
Output: 100%
Winding: 100% copper wire
Pole: 4pole/2pole
Product Name: LANDTOP YC single phase 2hp ac electric synchronous electrical motor
Packaging Details: carton box or plywood case

LANDTOP YC single phase 2hp ac electric asynchronous electrical motor

1). YC series single-phase asynchronous motor is commonly known as a capacitor start motor. Single phase motor stator winding has a primary winding and a secondary winding, the phase difference of 90 degrees in space, We know that the single-phase motor is the main winding of the magnetic field is generated pulsating magnetic field, through the secondary winding and capacitor split phase, in order to produce a fixed rotation direction of the magnetic field, when the speed exceeds the70-80% role, the centrifugal switch will cut off the secondary winding and the start capacitor, capacitor start motor is characterized by large starting torque, starting torque is greater than 1.8, low power factor, used to start demanding situations, cast iron shell motor.
2). YC series heavy-duty capacitor start motor, YC series of small power motors, aluminum shell MC series capacitor start motor. Structure must have a centrifugal switch and starting capacitor, with a high starting torque and good operation performance, small volume, light weight, low noise, convenient maintenance. YC series single-phase asynchronous motor applied to general machinery and equipment without special requirements, such as agricultural machinery, food machinery, fan, water pump, machine, mixing machine, air compressor.

Key words
single phase 2hp electric motor electrical motor ac asynchronous motor

Operation condition
Ambient temperature: -15℃≤θ≤40℃
Altitude: ≤1000m
Protection class: IP44
Insulation class: B/F
Rated voltage: 220V, other voltage on request
Cooling type: IC 0141
Duty: Continuous(S1)
Rated frequency: 50HZ, other frequency on request.
Technical data

TypeOut
put
Voltage(V)Current(A)Freq.(Hz)PowerfactorEff(%)Speed (r/min)Tstart/TnIst/InTmax/Tn
kWHP
YC90S-21.11.52207.2500.9573.228802.861.8
YC90L-21.522208.9500.977629002.871.8
YC100L-22.2322013.2500.9678.8290036.51.8
YC90S-40.7512205500.9373.314502.86.51.8
YC90L-41.11.52207.8500.97514502.561.8
YC100L-41.522209.3500.9279.414502.871.8
YC112M-42.2322013.6500.981.614502.36.51.8
YC132S1-43422018.2500.983.214502.16.51.8
YC132S2-43.7522022500.984.914502.16.51.8
YC132M1-45.57.522032.5500.985146026.51.8
YC132M2-47.51022040500.985.5146026.51.8
Company Information

LANDTOP GROUP is specialized in manufacturing and exporting a wide range of electromechanical products, covering Alternators, Generators, Electric Motors etc. With years of development, LANDTOP has developed into a large-scale, modern, comprehensive and international company. Our sales department is located in HangZhou City (HangZhou Landtop Co., Ltd. ), a sea-port city, enjoying convenient transportation network. We also have our own factory in HangZhou City (HangZhou Landtop Power Co., Ltd. ). Our international center is located in Hongkong (Hongkong Landtop Group Ltd. ). Our group is equipped with a great number of precise assemble lines, integrated testing systems and checkout equipment. We have professional engineers, skilled QC members, experienced salesmen and the best after-sales services. The current annual export production value is over 15 million US dollars.

Production Line

The procedure we make
1. Stamping of lamination2. Rotor die-casting3. Winding and inserting – both manual and semi-automatically4. Vacuum varnishing5. Machining shaft, housing, end shields, etc…6. Rotor balancing7. Painting – both wet paint and powder coating8. assembly9. Packing10. Inspecting spare parts every processing11. 100% test after each process and final test before packing.

Our advantagesDirectly Manufacturer – Over 10 years experience in electric motor field1.100% Copper wire and output 2.OEM Service 3.CE/ISO Approved 4.20-30days lead time
5.We are Alibaba Assessed Gold Supplier and Trade Assurance6.Best production capability, best quality control, best service, also best price
An electric motor from materials to full assemble motor, must pass 15 times check, and 100% testing of output power & voltage & electric current & non-load, 50% load, 75% load, 100% load, and also check the nameplate and packing. Finally shipping to our customers.

Certificates & Exhibition

Packaging & Shipping
FAQQ: Do you offer OEM service?
A: Yes
Q: What is your payment term?
A: 30% T/T in advance, 70% balance when receiving B/L copy Or 100% irrevocable L/C at sight.
Q: What is your lead time?
A: About 20-30 days after receiving advance deposit or original L/C.
Q: What certificates do you have?
A: We have CE, ISO. And we can apply for specific certificate for different country such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.
Q: What warranty do you provide?
A: One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.

What Is a Gear Motor?

A gear motor is an electric motor coupled with a gear train. It uses either DC or AC power to achieve its purpose. The primary benefit of a gear reducer is its ability to multiply torque while maintaining a compact size. The trade-off of this additional torque comes in the form of a reduced output shaft speed and overall efficiency. However, proper gear technology and ratios provide optimum output and speed profiles. This type of motor unlocks the full potential of OEM equipment.

Inertial load

Inertial load on a gear motor is the amount of force a rotating device produces due to its inverse square relationship with its inertia. The greater the inertia, the less torque can be produced by the gear motor. However, if the inertia is too high, it can cause problems with positioning, settling time, and controlling torque and velocity. Gear ratios should be selected for optimal power transfer.
The duration of acceleration and braking time of a gear motor depends on the type of driven load. An inertia load requires longer acceleration time whereas a friction load requires breakaway torque to start the load and maintain it at its desired speed. Too short a time period can cause excessive gear loading and may result in damaged gears. A safe approach is to disconnect the load when power is disconnected to prevent inertia from driving back through the output shaft.
Inertia is a fundamental concept in the design of motors and drive systems. The ratio of mass and inertia of a load to a motor determines how well the motor can control its speed during acceleration or deceleration. The mass moment of inertia, also called rotational inertia, is dependent on the mass, geometry, and center of mass of an object.
Motor

Applications

There are many applications of gear motors. They provide a powerful yet efficient means of speed and torque control. They can be either AC or DC, and the two most common motor types are the three-phase asynchronous and the permanent magnet synchronous servomotor. The type of motor used for a given application will determine its cost, reliability, and complexity. Gear motors are typically used in applications where high torque is required and space or power constraints are significant.
There are two types of gear motors. Depending on the ratio, each gear has an output shaft and an input shaft. Gear motors use hydraulic pressure to produce torque. The pressure builds on one side of the motor until it generates enough torque to power a rotating load. This type of motors is not recommended for applications where load reversals occur, as the holding torque will diminish with age and shaft vibration. However, it can be used for precision applications.
The market landscape shows the competitive environment of the gear motor industry. This report also highlights key items, income and value creation by region and country. The report also examines the competitive landscape by region, including the United States, China, India, the GCC, South Africa, Brazil, and the rest of the world. It is important to note that the report contains segment-specific information, so that readers can easily understand the market potential of the geared motors market.

Size

The safety factor, or SF, of a gear motor is an important consideration when selecting one for a particular application. It compensates for the stresses placed on the gearing and enables it to run at maximum efficiency. Manufacturers provide tables detailing typical applications, with multiplication factors for duty. A gear motor with a SF of three or more is suitable for difficult applications, while a gearmotor with a SF of one or two is suitable for relatively easy applications.
The global gear motor market is highly fragmented, with numerous small players catering to various end-use industries. The report identifies various industry trends and provides comprehensive information on the market. It outlines historical data and offers valuable insights on the industry. The report also employs several methodologies and approaches to analyze the market. In addition to providing historical data, it includes detailed information by market segment. In-depth analysis of market segments is provided to help identify which technologies will be most suitable for which applications.
Motor

Cost

A gear motor is an electric motor that is paired with a gear train. They are available in AC or DC power systems. Compared to conventional motors, gear reducers can maximize torque while maintaining compact dimensions. But the trade-off is the reduced output shaft speed and overall efficiency. However, when used correctly, a gear motor can produce optimal output and mechanical fit. To understand how a gear motor works, let’s look at two types: right-angle geared motors and inline geared motors. The first two types are usually used in automation equipment and in agricultural and medical applications. The latter type is designed for rugged applications.
In addition to its efficiency, DC gear motors are space-saving and have low energy consumption. They can be used in a number of applications including money counters and printers. Automatic window machines and curtains, glass curtain walls, and banknote vending machines are some of the other major applications of these motors. They can cost up to 10 horsepower, which is a lot for an industrial machine. However, these are not all-out expensive.
Electric gear motors are versatile and widely used. However, they do not work well in applications requiring high shaft speed and torque. Examples of these include conveyor drives, frozen beverage machines, and medical tools. These applications require high shaft speed, so gear motors are not ideal for these applications. However, if noise and other problems are not a concern, a motor-only solution may be the better choice. This way, you can use a single motor for multiple applications.
Motor

Maintenance

Geared motors are among the most common equipment used for drive trains. Proper maintenance can prevent damage and maximize their efficiency. A guide to gear motor maintenance is available from WEG. To prevent further damage, follow these maintenance steps:
Regularly check electrical connections. Check for loose connections and torque them to the recommended values. Also, check the contacts and relays to make sure they are not tangled or damaged. Check the environment around the gear motor to prevent dust from clogging the passageway of electric current. A proper maintenance plan will help you identify problems and extend their life. The manual will also tell you about any problems with the gearmotor. However, this is not enough – it is important to check the condition of the gearbox and its parts.
Conduct visual inspection. The purpose of visual inspection is to note any irregularities that may indicate possible problems with the gear motor. A dirty motor may be an indication of a rough environment and a lot of problems. You can also perform a smell test. If you can smell a burned odor coming from the windings, there may be an overheating problem. Overheating can cause the windings to burn and damage.
Reactive maintenance is the most common method of motor maintenance. In this type of maintenance, you only perform repairs if the motor stops working due to a malfunction. Regular inspection is necessary to avoid unexpected motor failures. By using a logbook to document motor operations, you can determine when it is time to replace the gear motor. In contrast to preventive maintenance, reactive maintenance requires no regular tests or services. However, it is recommended to perform inspections every six months.

China wholesaler LANDTOP YC single phase 2hp ac electric synchronous electrical motor     motor brushesChina wholesaler LANDTOP YC single phase 2hp ac electric synchronous electrical motor     motor brushes
editor by czh